Imaging modes
- Widefield EPI fluorescence (DAPI, GFP, mCherry, Cy5)
- Phase (10x, 20x)
- DIC (20x, 40x, 100x)
- TIRF (adhesive cell membrane), motorized TIRF angle
- dSTORM (super-resolution, single molecule localization)
- FRAP/ PA (photo activation/ conversion)
- Live-cell incubator (temperature, CO2, humidity)
Lasers (max. intensities out of 100x objective)
- 405 nm : 3.31 mW
- 488 nm : 53.5 mW
- 561 nm : 37.4 mW
- 647 nm : 80.7 mW
Emission filters
High speed emission filter wheel (OptoSpin IV) for clean multi-color imaging:
Filter |
λ/Bandwidth |
GFP |
525/50 |
mCherry |
600/37 |
Cy5 |
635 LP |
Emission splitter (OptoSplit III) for simultaneous 2- or 3-color imaging:
SD-dSTORM cube |
|
AF568, mCherry |
|
AF647, CF680 |
|
Triple cube |
|
GFP, AF488 (525/50) |
|
AF568, mCherry (600/37) |
|
AF647, CF680 (700/75) |
Detectors
- Camera 1 (left port): EMCCD, Andor iXon Ultra X3 987, 512×512 pixels, 16 µm pixel size, 56 fps full frame, QE max. 90%
- Camera 2 (right port): sCMOS, Photometrics Prime 95B (95% QE, 1200×1200 pixels, 11 µm pixel size, 41 fps full frame, 82 fps@12-bit)
- Camera 3 (left port front): CMOS, The Imaging Source DMK 23UX249 (1920×1200 pixels, 5.86 µm pixel size, 30 fps full frame)
Objectives
Mag. |
Type |
Immer. |
NA |
WD [μm] |
Info |
10x |
Plan Flour |
Air |
0.3 |
15,200 |
Ph1 DL |
40x |
Plan Flour |
Oil |
1.3 |
240 |
DIC H N2 |
60x |
Plan Apo |
Oil |
1.4 |
130 |
λ |
100x |
Plan Apo |
Oil |
1.5 |
120 |
DIC H N2 TIRF |
(All objectives have an external phase contrast)
Special
- 2x beam condenser for small FOV (dSTORM)
- Ultra-fast laser switching/ tuning (triggered acquisition)
Further information:
https://bua.openiris.io/Landing/Res...Possible user: No restrictions
Conditions of use:
The User and PI hereby declare to have understood and accepted the AMBIO User Guidelines and Rules
including the Safety Rules, as available online at: https://ambio.charite.de/fileadmin/user_upload/microsites/ohne_AZ/sonstige/ambio/Procedures/AMBIO_User-Guidelines-Rules_2025-01-30.pdf. It is further
understood that these Guidelines and Rules may be updated or changed in agreement with the AMBIO
steering committee. Registered Users and PIs will be notified of essential changes (service fees).
Furthermore, the new User and PI have understood that a fee will be charged for the usage of AMBIO services
as outlined in the AMBIO User Guidelines and Rules, and that they are willing and able to pay the fees.
Note
New users – access upon training request here.
Email: ambio@charite.de
Provider:
Advanced Medical BIOimaging Core Facility
Provider Location:
Campus Charité Mitte (CCM)
CharitéCrossOver (CCO)
Rm 01-306
Virchowweg 6
10117 Berlin
Germany
Location:
Charité Campus Mitte
CCO Rm. 01-306
Virchowweg 6
10117 Berlin
Germany
Similar service offers
Magnetic Resonance Imaging (MRI)
Magnetic Resonance Imaging System
Carrier
Charité
Usable by
HU | TU | FU | Charité
Electron Micrscopy
Scanning Electron Microscope (SEM)
Carrier
Charité
Usable by
HU | TU | FU | Charité
Magnetic Resonance Imaging (MRI)
Magnetic Resonance Imaging System
Carrier
Charité
Usable by
HU | TU | FU | Charité