Imaging Modes
- Transmitted light with oblique contrast for sample positioning and overview
- Reflected light and epifluorescence with laser for beam adjustment and fluorescence light sheet imaging
- ibidi stage top incubation system (temperature, CO2, humidity) and integrated auto-immersion mechanism enable unattended long-term experiments
- Photo-manipulation: 405 and 473 nm and lasers for FRAP and photo-activation/photo-switch and 780 nm laser for ablation experiments
Acquisition
- Speed: Volume: 3 Vol/s @300 μm x 50 μm x 20 μm, plane: 400 frames/s @300 μm x 20 μm
- Penetration depth up to 80 – 200 μm
Illumination
- LED (white & red) for transmitted light
- Laser for reflected light & epi-fluorescence: 488 nm (2 mW), 561 nm (2 mW), 640 nm (1 mW)
Detectors
- pco.edge 4.2 CLHS sCMOS camera (2048×2048 pixels, 300 x 300 µm, 100 fps@16-bit full frame, 82% QE, 6.5 µm pixel size)
Software
- ZEN 3.5 (blue edition)
- Lattice Lightsheet Processing Module (deskewing, coverglass transformation)
- arivis Vision4D® software for advanced stitching, channel shift, high resolution volume rendering, and powerful deconvolution
Special
- Ultra-fast live 3D subcellular imaging with minimal phototoxicity and bleaching
- Near-isotropic resolution along the X, Y, and Z axes
- Using standard coverslips, 35 mm cell culture imaging dishes or well plates
- 5-axes stage tilt-able with high precision in X and Y
- Automatic water immersion dispenser
Objectives/Optics
- Illumination (light sheet): 13.3x / NA 0.4
- Detection: 44.83x / NA 1.0
Filters
Filter (λ, Bandwidth) | Sample Fluorophore |
LBF 405/ 488/ 561/ 642 | All, blocks excitation laser |
BP 495-550/ BP 570-620 | GFP, mCherry |
BP 495-550 +LP655 | GFP, Cy5 |
BP 570-620 +LP655 | mCherry, Cy5 |
BP 495-590 | GFP, YFP, mCherry |
EF LP 570 | mCherry, Cy5 |
Further information:
https://bua.openiris.io/Landing/Res...Possible user: No restrictions
Conditions of use:
The User and PI hereby declare to have understood and accepted the AMBIO User Guidelines and Rules
including the Safety Rules, as available online at: https://ambio.charite.de/fileadmin/user_upload/microsites/ohne_AZ/sonstige/ambio/Procedures/AMBIO_User-Guidelines-Rules_2025-01-30.pdf. It is further
understood that these Guidelines and Rules may be updated or changed in agreement with the AMBIO
steering committee. Registered Users and PIs will be notified of essential changes (service fees).
Furthermore, the new User and PI have understood that a fee will be charged for the usage of AMBIO services
as outlined in the AMBIO User Guidelines and Rules, and that they are willing and able to pay the fees.
Note
New users – access upon training request here.
Email: ambio@charite.de
Provider:
Advanced Medical BIOimaging Core Facility
Provider Location:
Campus Charité Mitte (CCM)
CharitéCrossOver (CCO)
Rm 01-306
Virchowweg 6
10117 Berlin
Germany
Location:
Charité Campus Mitte
CCO Rm. 01-307
Virchowweg 6
10117 Berlin
Germany
Similar service offers
Magnetic Resonance Imaging (MRI)
Magnetic Resonance Imaging System
Carrier
Charité
Usable by
HU | TU | FU | Charité
Light Microscopy
Confocal Microscope
Carrier
Charité
Usable by
HU | TU | FU | Charité
Magnetic Resonance Imaging (MRI)
Magnetic Resonance Imaging System
Carrier
Charité
Usable by
HU | TU | FU | Charité