Imaging Modes
- Spinning disk confocal (DAPI, CFP, GFP, YFP, mCherry, TxRED, Cy5)
- SoRa-mode (Super Resolution by Optical Pixel Reassignment, 1.4x resolution improvement)
- FRAP/ PA (photo activation/ conversion)
- Widefield EPI fluorescence mode (DAPI, GFP, TxRED, TRITC-B, Cy5)
- DIC for 10x, 40x, 60x, 100x objectives (upon request)
- Live-cell incubator (temperature, CO2, humidity)
7 Laser Lines
- 405 nm
- 445 nm
- 488 nm
- 515 nm
- 561 nm
- 594 nm
- 638 nm
Detectors
- 2x Hamamatsu ORCA-Fusion digital sCMOS cameras (2304×2304 pixels, 100 fps @ 2304×2048 pixels, 80% QE, 6.5 µm pixel size)
- Dual-camera system for simultaneous dual-color detection (e.g. GFP/RFP, RFP/SiR, GFP/SiR, upon request)
Software
- NIS-Elements AR (Advanced Research) including modules for:
- JOBS (automation)
- Deconvolution
- NIS.ai (Artificial Intelligence): denoise, clarify, enhance, segment, convert
Special
- Nipkow CSU-W for large FOV 1024×1024 px [size in µm for 10x]
- Uniform spinning disk illumination
- Enhanced signal-to-noise ratio compared to CSU-X
- 2 cameras for simultaneous dual-color imaging
- Fast emission filter wheel for clean multi-color imaging
- Ultra-fast laser switching for triggered multicolor acquisition
- SoRa-mode: Enhanced resolution (1.4x) in spinning disk mode
- Automatic water immersion dispenser (WID)
Emission Filters
Filter | λ/Bandwidth |
Quadband (DAPI, GFP, mCherry, Cy5) | 440/40 521/21 607/34 700/45 |
DAPI | 447/60 |
CFP | 472/30 |
GFP | 525/50 |
YFP | 542/27 |
mCherry | 600/50 |
Cy5 | 685/40 |
Objectives
Mag. | Type | Immer. | NA | WD [μm] | Info |
10x (not installed) | Plan Achroat | Air | 0.45 | 4,000 | DIC N1 λ OFN25 |
40x | Apo LWD | Water | 1.15 | 600 | DIC N2 λS |
60x | Plan Apo | Water | 1.2 | 310-280 | DIC N2 VC OFN25 |
60x | Plan Apo | Oil | 1.4 | 130 | DIC N2 λ OFN25 |
25x | Plan Apo | Silicone | 1.05 | 550 | DIC N2 λS OFN25 |
40x | Plan Apo | Silicone | 1.25 | 300 | DIC N2 λS OFN25 |
100x | Plan Apo | Silicone | 1.35 | 300-290 | SR HP DIC N2 λS OFN22 |
Weiterführende Informationen:
https://bua.openiris.io/Landing/Res...Mögliche Nutzer:innengruppen: No restrictions
Nutzungsvoraussetzungen:
The User and PI hereby declare to have understood and accepted the AMBIO User Guidelines and Rules
including the Safety Rules, as available online at: https://ambio.charite.de/fileadmin/user_upload/microsites/ohne_AZ/sonstige/ambio/Procedures/AMBIO_User-Guidelines-Rules_2025-01-30.pdf. It is further
understood that these Guidelines and Rules may be updated or changed in agreement with the AMBIO
steering committee. Registered Users and PIs will be notified of essential changes (service fees).
Furthermore, the new User and PI have understood that a fee will be charged for the usage of AMBIO services
as outlined in the AMBIO User Guidelines and Rules, and that they are willing and able to pay the fees.
Hinweis
New users – access upon training request here.
E-Mail: ambio@charite.de
Anbieter:
SupraFAB
Standort Anbieter:
Freie Universität Berlin
Standort:
SupraFAB
Altensteinstraße 23a
14195 Berlin
Room 101
Ähnliche Service-Angebote
Elektronenmikroskopie
Rasterelektronenmikroskop (SEM)
Betreiber
HU
Nutzbar durch
HU | TU | FU | Charité
Transmissionselektronenmikroskop (TEM)
Measurement of electrostatic fields and potentials (TEM/STEM)
Betreiber
TU Berlin
Elektronenmikroskopie
Kryo-Transmissions-Elektronenmikroskop (cryoTEM)
Betreiber
Charité
Nutzbar durch
HU | TU | FU | Charité