Nikon Widefield Ti2
Charité Campus Mitte, CCO, Rm. 01-307, Virchowweg 6, 10117 Berlin, Germany
Specifications
MAIN FEATURE: Fast high-throughput multiplex 3D live-cell screening
- Multi-color, long-term time series, multi-position / multi-well plates, large image scan
- Fully motorized high precision stage for accurate XYZ-repositioning
- Focus drift correction (Nikon Perfect Focus System)
- Live-cell incubator (temperature, CO2, humidity, carbogen)
- Automatic water immersion dispenser (WID) for water immersion objectives for high-resolution on water-based samples
- Perfusion
Imaging Modes
- Widefield epifluorescence (DAPI, CFP, GFP, YFP, mCherry, Cy5)
- Bright-field (transmitted light) for histological slides (color stains)
- Automated phase contrast for 10x & 20x objectives
- FRET
- Interference reflection microscopy (IRM)
- Polarized light microscopy
Special
- Fast LED switching/ tuning (triggered acquisition)
- Fast triggered emission filter wheel for clean multi-color imaging of DAPI, CFP, GFP, YFP, mCherry, and Cy5
- NIS-Elements AR (Advanced Research) software including modules for:
- Automated acquisition & feedback microscopy (NIS-Elements JOBS module)
- 2D & 3D Deconvolution
- NIS.ai (Artificial Intelligence): denoise, clarify, enhance, segment, convert
LED Illumination (Lumencore, SpectraX)
- 395/25 nm
- 438/29 nm
- 475/28 nm
- 511/16 nm
- 555/28 nm
- 635/22 nm
Detectors
- For fluorescent samples: sCMOS, PCO.edge camera (>80% QE, 2048×2048 pixels, 6.5 µm pixel size, 53 fps full frame, up to 500 fps in small area)
- For stained samples (histology): Nikon DS-Ri2 color CMOS camera (4908×3264 pixels, 6 fps full frame, 45 fps in 1636×1088 pixels)
Emission Filters
- QUAD (λ/Bandwidth (example fluorophor))
- 435/33 (DAPI)
- 520/26 (GFP)
- 595/38 (mCherry)
- 695/63 (Cy5)
- 482/35 (CFP)
- 540/30 (YFP)
- 519/26 (GFP)
- 595/31 (mCherry)
- 697/60 (Cy5)
Objectives
- 4x PlanApo λ Air NA 0.2 WD 20 µm
- 10x PlanFluo Ph1 DL Air NA 0.3 WD 15,2 µm
- 20x PlanApo Ph2 DM Air NA 0.75 WD 1 µm
- 40x Plan Apo λ DIC N2 Air NA 0.95 WD 0.250 – 0.170 µm
- 40x Apo LWD λS DIC N2 Water NA 1.15 WD 0.590 – 610 µm
- 60x Plan Apo λ DIC N2 Oil NA 1.4 WD 0.130 µm
Weiterführende Informationen:
https://bua.openiris.io/Landing/Res...Mögliche Nutzer:innengruppen: Keine Einschränkung
Nutzungsvoraussetzungen:
The User and PI hereby declare to have understood and accepted the AMBIO User Guidelines and Rules
including the Safety Rules, as available online at: https://ambio.charite.de/fileadmin/user_upload/microsites/ohne_AZ/sonstige/ambio/Procedures/AMBIO_User-Guidelines-Rules_2025-01-30.pdf. It is further
understood that these Guidelines and Rules may be updated or changed in agreement with the AMBIO
steering committee. Registered Users and PIs will be notified of essential changes (service fees).
Furthermore, the new User and PI have understood that a fee will be charged for the usage of AMBIO services
as outlined in the AMBIO User Guidelines and Rules, and that they are willing and able to pay the fees.
Hinweis
New users – access upon training request here.
E-Mail: ambio@charite.de
Anbieter:
Advanced Medical BIOimaging Core Facility
Standort Anbieter:
Campus Charité Mitte (CCM)
CharitéCrossOver (CCO)
Rm 01-306
Virchowweg 6
10117 Berlin
Germany
Standort:
Charité Campus Mitte
CCO Rm. 01-307
Virchowweg 6
10117 Berlin
Germany
Ähnliche Service-Angebote
Magnetresonanztomographie (MRT)
Magnetresonanztomographie-System
Betreiber
Charité
Nutzbar durch
HU | TU | FU | Charité
Elektronenmikroskopie
Transmissionselektronenmikroskop (TEM)
Betreiber
HU
Nutzbar durch
HU | TU | FU | Charité
Elektronenmikroskopie
Rasterelektronenmikroskop (SEM)
Betreiber
Charité
Nutzbar durch
HU | TU | FU | Charité